Before You Begin
Important Warnings
Plastic ozone supply tubing is supplied with the DEL Ozone generator. Never replace this tubing with metal tubing.
Short-term inhalation of high concentrations of ozone and long term inhalation of low concentrations of ozone can cause serious harmful physiological effects.
DO NOT inhale ozone gas produced by this device.
Select Ozone Model for Specifications
![]()
There are 3 different Ozone models. Choose your model to see specific power requirements and additional specifications.
Ozone 50
Ozone 100
Specifications for Ozone 25
Power Requirements: 110-250V, 0.10A max, 50-60 Hz
Mounting: Wall mount in a clean, protected area.
Ambient Temperature: 30°F – 120°F (0°C – 50°C)
Specifications for Ozone 50
Power Requirements: 110-250V, 0.20A max, 50-60 Hz
Mounting: Wall mount in a clean, protected area.
Ambient Temperature: 30°F – 120°F (0°C – 50°C)
Specifications for Ozone 100
Power Requirements: 110-250V, 0.31A max, 50-60 Hz
Mounting: Wall mount in a clean, protected area.
Ambient Temperature: 30°F – 120°F (0°C – 50°C)
Pool Set Up
This is an example only of a common configuration for set up purposes.
The unit must be installed in an outdoor location (out of direct sunlight), or indoors in a forced air ventilated room.
Verify it is inaccessible to a person in the pool and in an area at least 5 feet (1.5 meters) from wall of pool using nonmetallic tubing.
Make sure ozone generator will be no less than one (1) foot above maximum water level to prevent water from contacting electrical equipment. Keep out of reach of sprinklers or drainage spouts.
Make sure generator has adequate water drainage to protect electrical components.
Pool and Spa Combo
This is an example only of a common configuration for set up purposes.
The unit must be installed in an outdoor location (out of direct sunlight), or indoors in a forced air ventilated room.
Verify it is inaccessible to a person in the pool and in an area at least 5 feet (1.5 meters) from wall of pool using nonmetallic tubing.
Make sure ozone generator will be no less than one (1) foot above maximum water level to prevent water from contacting electrical equipment. Keep out of reach of sprinklers or drainage spouts.
Make sure generator has adequate water drainage to protect electrical components.