Bobé Fire Pot & Fire Table Installation

LOCATION

Provide Adequate Drainage

Pots and tables should have adequate drainage for rainwater. Vent collars will provide built-in drainage – do not impede drainage.

Select a location with adequate drainage. All bowls, fire pits and enclosures must be drained to prevent water from accumulating. 

Ensure Correct Clearance & Access

ACCESS: Leave easy adequate access for installation and maintenance.

Recommended Clearances: Sides 4 ft / Top 10 ft: Combustibles/structures not to be closer than 4’ on the horizontal plane, 10’ overhead. (FIG 1). 

  • No combustible structure should be above the fire feature. No more than two side structures should be around the fire feature.
  • Do not recess the fire feature below ground/floor level
  • Natural stone such as granite or marble must be kept away from heat and flame. Contact and close proximity can result in cracking or explosion. 
  • Install fire features out of the way of pedestrian traffic. Provide space to allow a safe distance from the heat and flame.

Base Setup

The base of all fire pots are open for plumbing/gas. The base is half the diameter of the width.

Pots and tables should always be installed on a level surface.

Weight of pots and tables will hold them in place, but a construction adhesive or screws can also be used for extra security.