Injector Tube Adapter Replacement
Before Servicing
Disconnect power before proceeding.
Do not tighten past 10 in-lbs torque or the injector tube adapter could be damaged.
Removing the Injector Tube Adapter
The injector tube adapter connects the ozone gas line to the injector manifold.
- Remove if worn or dirty.
- Loosen or remove the tubing clamp. Use pliers if necessary to twist and unlock the clamp.
- Pull the tubing from injector tube adapter and unthread the adapter from the injector.
Replacing the Injector Tube Adapter
- Apply Teflon® based thread sealant
- Install new connector
- Thread the adapter onto the injector
- Push the tubing into injector tube adapter
- Reapply the tubing clamp. Use pliers if necessary to twist and lock the clamp. Do NOT tighten over 10 in*lb.