System Start-Up

Pool Preparation

To achieve optimal performance from the ozone system, the pool must be as clean as possible to start with.

1. Backwash or clean filters one day before starting the ozone generator.

2. Superchlorinate pool water using a chlorine based shock treatment prior to ozone system start-up.

3. Test pool chemistry and adjust pH between 7.4 and 7.6. Adjust total alkalinity between 80 and 120 ppm.

4. Run pool filtration continuously for 24 hours prior to starting ozone system.

Checking Ozone Indicators

Upon completing all of the generator system connections and cleaning the pool, you are ready to start the ozone generator.

 

Ozone 25
Ozone 50
Ozone 100

Ozone 25 Indicators

1. Check electrical connections.

2. Check for proper voltage.

3. Turn on pool circulation system. The DEL Ozone generators are constructed with high voltage plasma gap ozone modules. When the pool’s circulation system starts, the DEL Ozone generator will power up and the green indicator lights on the ozone cells will illuminate.

4. Open the enclosure door to verify that all indicator lights are green. The Ozone 25 has 2 modules/ light indicators. The indicator lights signal that it’s working properly.

 

 

Ozone 50 Indicators

1. Check electrical connections.

2. Check for proper voltage.

3. Turn on pool circulation system. The DEL Ozone generators are constructed with high voltage plasma gap ozone modules. When the pool’s circulation system starts, the DEL Ozone generator will power up and the green indicator lights on the ozone cells will illuminate.

4. Open the Enclosure Door to verify that all indicator lights are green. The Ozone 50 has 4 modules/ light indicators. The indicator lights signal that it’s working properly.

Ozone 100 Indicators

1. Check electrical connections.

2. Check for proper voltage.

3. Turn on pool circulation system. The DEL Ozone generators are constructed with high voltage plasma gap ozone modules. When the pool’s circulation system starts, the DEL Ozone generator will power up and the green indicator lights on the ozone cells will illuminate.

4. Open the Enclosure Door to verify that all indicator lights are green. The Ozone 100 has 6 modules/ light indicators. The indicator lights signal that it’s working properly.

certificate icon

Congratulations!

You have completed this chapter. To go to the next chapter, click next. To go back to the Chapter Table of Contents, click done.