The Feeder

Recharging the Feeder

  1. Turn control valve to the closed position (counter clockwise). SHUT OFF PUMP.
  2. Wait one minute allowing the water and fumes to drain from the feeder.
  3. Leave the control valve closed and turn on the pump. (The check valve will prevent water from entering the feeder).
  4. Remove cap and fill with tablets.
  5. Replace cap making sure o-ring is clean, lubricated, and in place. (Hand tighten only).
  6. Open control valve (clockwise) to original setting.

Cleaning a Cloudy Lid

If the glass lid becomes cloudy, turn off the feeder using the recharging instructions.

Remove the lid and wipe clean.

If it remains cloudy, it will clear itself if left exposed to sunlight and fresh air.

DO NOT leave chlorinator open without the lid installed.

If the lid must be left off to clear up, a replacement must be installed temporarily.

Winterizing the Feeder

This chlorinator has a drain plug located on the bottom for easy draining of the unit for winter.