The LED Waterfall lights are not operating as expected with the Colorwheel Control
Here are troubleshooting tests that can be performed by a service professional:
CONTROLLER TEST
- Check voltage with meter. Incoming power should be 12VDC into controller. Not 12VAC.
- Disconnect Wires from Output side of controller.
- Turn on power to controller and power up controller.
- Check output voltage.
- Connect Positive lead to the “+” terminal, connect Negative lead to the “R” terminal
- Cycle modes until you see DC voltage (level could vary)
- Repeat by switching Negative lead to the “G” and “B” terminals
- If DC voltage is seen on all of the terminals the controller is in good working condition.
LED TEST
- Power up LED Waterfall Transformer
- Check output voltage with meter. Should show 12VDC. Not 12VAC. If 12VDC power is shown please proceed with the following steps.
- Connect the White wire from Waterfall to the Red output wire from Transformer
- Connect the Red wire from Waterfall to the Black output wire from Transformer (Red color should be shown on LED Strip)
- Repeat be switching out the Red Waterfall wire to the Green Waterfall wire (Green color should be shown on LED Strip)
- Repeat be switching out the Green Waterfall wire to the Black Waterfall wire (Blue color should be shown on LED Strip)
- If any color does not appear when connected there is a break in the wire or the strip is in bad working order.