Ozone Module Replacement
When to Replace
Replace Ozone Modules if the Ozone Module Indicator will not light, or after 15,000 hours of operation (15,000 hours equals approximately 5 years for a pool system that operates 8 hours/day).
Detach
Remove the Interconnect Tubing and Filters from the Ozone Cell connections on the outside of the DEL AOP S.
Remove the screws securing the Ozone Cells to the side of the enclosure.
Disconnect the power connectors between the Ozone Power Supplies and wire harness.
Removal
Remove the screws securing the Ozone Power Supply to the standoff inside of the enclosure.
Remove the Ozone Module.
Installation
Insert Ozone Module.
Replace the screws to secure the Ozone Power Supply to the standoff inside of the enclosure.
Reconnect the power connectors between the Ozone Power Supplies and wire harness.
Replace the screws securing the Ozone Cells to the side of the enclosure.
Replace the Interconnect Tubing and Filters from the Ozone Cell connections on the outside of the DEL AOP S.