Before you Begin

Important Warnings

IF POOL OR SPA HAS COPPER PLUMBING DO NOT INSTALL. This will damage the feeder.

To prevent over chlorination during use, completely close the control valve and the built in check valve will prevent chemical from being fed into the pool or spa.

CAUTION SHOULD BE USED WHEN REMOVING CAP. DO NOT INHALE FUMES

Heaters and other equipment may be damaged by highly chlorinated water.

If heaters are used, a Fireman’s Switch or equivalent must be installed to prevent possible damage and improper operation of check valve and other equipment subject to heat damage.

 

Chemical Warnings

This feeder is designed to use only Trichlor-s-triazinetrione OR Bromine tablets- slow dissolving type.

BROMINE MAY BE SUBSTITUTED FOR TRICHLOR IN THIS FEEDER. DO NOT MIX BROMINE AND TRICHLOR.

UNDER NO CIRCUMSTANCES MIX Trichlor or Bromine with Calcium Hydrochlorite, with other forms of concentrated chlorine or with other chemicals. FIRE AND/OR EXPLOSION MAY RESULT.

If you are not sure which chemical was used previously, flush thoroughly with fresh water.

NEVER use oils or grease to lubricate o-ring. Oil in contact with Trichlor OR Bromine may result in FIRE. Lubricate o-ring with approved silicone o-ring lubricant only.

Specifications

The Powerclean Ultra VS feeder comes with the Powerclean VS Low Flow Inlet, Cone and Outlet pre-installed.

These are for systems with 2-speed or variable speed pumps where the system flow is less than 50 gpm at the lower speed.

If the system uses only a single speed pump, or the low speed is over 50 gpm, remove the inserts.

Powerclean Ultra VS Performance Chart