Plumbing

Plumbing

The UV-C 50 can easily be added into the pool’s plumbing loop.

Simply connect the water inlet and outlet into the pool’s return line.

The UV-C 50 will come with union fittings installed on the Inlet and Outlet.

Use the fittings provided to connect the UV-C 50 inlet and outlet to your pool’s plumbing. (Inlet is at the bottom, outlet is at the top)

 

Direct Plumbing
Plumbing with Bypass Valve
Plumbing with Bypass Valve and Ozone
Below Water Level

Direct Plumbing

The UV-C 50 must be installed in the pool’s main return line after the filter, before the heater and any chlorine feeders or chlorine generators.

 

Once all plumbing connections are complete and glue has properly cured, start the circulation system and run at highest normal operating pressure.

Check for leaks at all external connections, and inside the UV-C 50 housing near the Quartz Tube seals.

Repair leaks as needed before proceeding.

Plumbing with Bypass Valve

The UV-C 50 must be installed in the pool’s main return line after the filter, before the heater and any chlorine feeders or chlorine generators.

 

Once all plumbing connections are complete and glue has properly cured, start the circulation system and run at highest normal operating pressure.

Check for leaks at all external connections, and inside the UV-C 50 housing near the Quartz Tube seals.

Repair leaks as needed before proceeding.

Plumbing with Bypass Valve and Ozone

The UV-C 50 must be installed in the pool’s main return line after the filter, before the heater and any chlorine feeders or chlorine generators.

 

Once all plumbing connections are complete and glue has properly cured, start the circulation system and run at highest normal operating pressure.

Check for leaks at all external connections, and inside the UV-C 50 housing near the Quartz Tube seals.

Repair leaks as needed before proceeding.

Plumbing below Water Level

The UV-C 50 must be installed in the pool’s main return line after the filter, before the heater and any chlorine feeders or chlorine generators.

Install required Flow Switch Kit (P/N EUV-FS-01) to ensure the system does not turn on without adequate flow.

 

Once all plumbing connections are complete and glue has properly cured, start the circulation system and run at highest normal operating pressure.

Check for leaks at all external connections, and inside the UV-C 50 housing near the Quartz Tube seals.

Repair leaks as needed before proceeding.

certificate icon