BALANCING THE FLOW

It is recommended to use a 3-way valve after the pump to allow the flow to be regulated between the waterfall and the pool return. The recommended location for this valve is after the filter near the equipment pad (Figure 7).

When plumbing two or more waterfalls, follow all of the previous instructions with the addition of a 2-way ball valve for each waterfall. The valve is necessary to balance the water flow between the units. Proper placement of the valve is shown in (Figure 8). CMP ball valve part numbers are 25800-151-000 for 1½” and 25800-210-000 for 2”.

 

NOTICE: Use only water that has been properly filtered by an in-line cartridge filter. Failure toproperly filter water may result in a clogged waterfall and a voided warranty.

 

To go back to table of contents, click done.